Answer Posted / minal
Generator transformer is called main transformer.The output
of a generator is connected to a main transformer. It steps
up the the generating voltage.
| Is This Answer Correct ? | 18 Yes | 6 No |
Post New Answer View All Answers
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
can anybody sent me power grid questions. what subject should i prefer for preparation?
what is data block in plc ? How the values of data block are written and read by hmi ? what is the difference between function and function block ?
Explain how you intend to work under pressure to meet up with deadline target?
Why using synchronising methed in DG's sets?
What is deference between MCB & MCCB & ISOLATOR
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
how to remover corona effect and hysteresis losses from contactor
What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
Explain about p.t?
What is the different between digital phase converter and ordinary phase converter?
determine two methods to find loose connection in operational electrical system?
When we use 3 terminal resistor?
What is current divider rule (cdr)?