my field of interest is T&D. plz tell something about that.
Answer Posted / balaji
T&D is a very vast feild in Electical Engg,It starts from
how power is transmitted & effectively distrubutd to user
end.Its is many areas like Loss reduction,Compensator
Design,Harmonics Compensation,Voltage Grading in Overhead
lines & Underground cable lines,HVDC(High Voltage DC
Transmission),FACT(Flexiable AC Transmission),SCADA
(Supervisory Data Control And Aquactions System)
Controlling,Protection,Montoiring,Metering(PT,CT,Optical
CT),Circuit Breaker(Vacuum Circuit Breaker,Ring Main
Unit,Isolator,Disconnector,Gas Insulated Subsataion,SF6
Breaker,Fuses),Substation Design,Pole Insulator Design
(Bushings)and latest Solid state circuit breaker, these are
major feild which seems to interesting
Is This Answer Correct ? | 12 Yes | 0 No |
Post New Answer View All Answers
Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
grr resistance & contrator malt continuous
sir, Is their any measuring unit of knoking? please explian?
what is the safety of voltage power transformer(2250KVA0
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com
Electronic circuit
What is the need of generator relay panel
How to select a contactor? How many types of contactors are available
how we provide neutral earth on synchronising panel as per electrical standards?
our industries ht line so power fluctation(once drop of power please rectify causes
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
what is sevice settings for mccb?How can be it setted?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible