whether the generating voltage can be made to be
transmitted by means of signals to the recieved end or at
the consumers end?

Answer Posted / balaji

Yes, it is possible
For any Wave propogation we need a meduim, which can be
defined alpha+jbeta;alpha denotes for conductive meduim &
beta for attenuation.So by proper tuning of alpha & beta we
can transmitt.Secondly we can use Ionosphere as we using in
Radiowave, on this concepts many Japanese Reserach
Institute are working currently

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?

2117


draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it

2197


Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks

3415


In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?

1513


what is negative d.c. voltage, why this voltage is used in base transciever station.

1735






How many types of circuit loads are there in a common electrical circuit?

678


I want to know how to calculate the size of electricity cable in building?

1532


explain why core loss of a transformer is almost constant under different load conditions when connected across a constant voltage and constant frequency.

2207


I'm looking for a mnaual set for a Teradyne J750. Softcopy would be preferred but I'll take what I can get.

1749


how can we calculate the ratio of caustic soda and water in lrs.

5179


WHY DO VOLTAGE TRANSFORMERS FAIL DURING EARTH FAULT IN THE DELTA CONNECTED 6.6KV ELECTRICAL SYSTEM

1540


Transformer how to maintaince a check b check c check d check

1531


What is a differential amplifier?

645


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1428


Why do we perform an open-circuit test and short-circuit test on the transformer?

630