WHAT IS THE DIFFERENCE BETWEEN RESISANTANCE AND IMPEDANCE
IF IMPEDANCE IS MORE THAN RESISTANCE AT SAME VOLTAGE CAN WE
HAVE RELATION DERIEVED BETWEEN THEM
Answer Posted / nimish
In A.C. supply reactance comes in to picture and in D.C.
supply there is a resistance.
z = R + jX
Is This Answer Correct ? | 5 Yes | 4 No |
Post New Answer View All Answers
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.
DG Earth Value?
How will be the single line diagram of series trip HT breaker? how it works?
What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?
What is the accepted limit to increase the choosen transformer capacity over the load and why ?
why don't we use the generator as a motor? and what will happen?
what are the maximum available current, voltage ratings and switching speeds of the power electronic devices thyristor, power mosfet, igbt, and mct?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
how to calculate voltage drop and followed by cable calculation?is there avail in formula?
what is the voltage regulation for unity and zero power factor?
if any house we instaled a 1.5 ton ac and its phase cable of wiring is installed but netrual cable of wiring not instaed. my question is that is neutual of house(for other wiring is capable for ac load or a sepeart neutrual wiring required
what is the difference between droop mode and ischnorous mode in thermal powerplant?
why single CT used in DOL starter power circuit?
How does zener phenomenon differ from avalanche breakdown?
Load transfer in 11kv double busbar switchgear - operation.