Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the diff. between two phase & three phase supply.

Answer Posted / v v r s

three phase supply means RYB AND NEUTRAL 4 WIRE SYSTEM

( phase to phase voltage is 415V and phase to neutral is
230V )

Two phase supply RY OR YB and neutral

Is This Answer Correct ?    83 Yes 42 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is magneto on a gas generator. how it functions. its out put is d.c or a.c. how it can be checked for correct functioning

2018


I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?

1677


what is circuit recombiner and how it is different from circuit breaker

1889


difference bewteen reverse current and alternating current

2240


do any one help me to get "C" license,, i have doubts ,,, if mediators ter pls call me,, my no is 8056640042

1438


I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2281


what is stper motor

2421


whati s the sludge current in ups

2251


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1668


How does a digital electronic meter work??????

2069


On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?

4380


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1756


Give two basic speed control scheme of dc shunt motor?

1104


why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?

1798


we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.

1922