how to calculate no. of earthing pits and their diamensions?
no. of lightning arrester rods which are required to
protect a building of 35 mtr and we calculate?
Answer Posted / mahamuni raja
to determine the no.of earthing pits required is depends
uponn the area required to dissipate the fault courrent to
the area of pipe electrode.
To protect 35M building , 1no. of lightning arrestor is
sufficient however better to provide two nos.of down
conductors hence to protect the building if any one
conductor fails.
| Is This Answer Correct ? | 29 Yes | 7 No |
Post New Answer View All Answers
What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan
The gauge indicates the number of amps, but what about voltage? How voltage rating (for wire or fuse) determined?
How capacitor improves pf
What are the basic elements used for modeling mechanical rotational system?
On what basis the the size of Lightning arrester for buildings are selected ?
i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?
How to calculate Voltage regulation of 22 KV Over head Line.
how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
pls tel me the electric train traction motors name plate details like rpm,torue,voltage,amps,watts..ect..
Leakage current,un balance current which relay using for high voltage transmission?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
how does high earth to neutral voltage affects electronic circuit?
what is ATS & RING MAIN UNIT in Distribution System?And its Function.
Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks