Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is derating factor in Cable ? how we minimise this?

Answer Posted / viral

Due to partial discharges in cable it can't be utilized to
it's rated capacity.
As current flowing to charge cable capacitance is extra
burden on that which will make it to carry less current for
load.
To reduce this good insulation material should be use.

Is This Answer Correct ?    57 Yes 61 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how will calculate the safe starting current of 3-phase squirrel cage induction motor?

1965


Make a list observation on Transformer?

2473


what is meant by 3rd hormonics ?

1907


explain Density

1172


How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx

2290


what is conductor copnstant of ab cable

1966


please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com

1976


Is there a standard depth of gravel fill in Substation Switchyard? Please give a design/drawing. Thank you.

5456


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

2107


I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.

2433


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9441


slipring induction motor starting time Lrs operating why lrs starting time lrs outer body didn't get shock

1969


how to calculate percentage impedence at 75 deg C at normal tap

2292


Is it required to use Automatic transfer Switch in L&T panel board if we use AMF panel with DG set? How the single line diagram will be? Please forward the material to sreenu_207@yahoo.co.in

4787


What is the reason that the humming sound is coming from the induction furnace panel?

2663