Stator of three phase induction motor creates Rotating
Magnetic field.But why not Transformer?

Answer Posted / vidhya

In the stator the three phase windings are seperated by
120' in space but in transformer no such
displacement...further RMF is formed only by the
interaction of stator flux and rotor flux...but no way to
produce 2-flux interaction in the case of transformer
because of the absence of airgap b/w the windings and the
core as it is wounded directly over the core..

Is This Answer Correct ?    17 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference b/w fanuc alpha series 16i and 18i controller. what is stand for i

1584


what is the pre charge circuit,what will be work which function it will be use plz tell me

1447


What is miller crystal oscillator? Explain its operation?

665


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1223


What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?

1436






what is the preventive maintence for ht panels and busbars and vcb abd acb's.

1850


how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?

2440


What is the vector group of a transformer,how can it be found out?

1569


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2282


UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?

1470


What is meant by control system?

665


What is called grain-oriented laminations?

617


Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV

1745


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1213


In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.

3392