hw to calculate flc of motor ? data are:3-phase,50Hz,30kw

Answer Posted / rajkumar r

U CAN FIND FLC OF THE MOTOR IN THE MOTOR NAME PLATE ITSELF.
MOREOVER,
1HP=0.746KW
1KW=1/0.746HP
30KW=30/0.746 HP=40HP

Practically current taken by 1HP motor=1.342A
so full load current of 30kw(40HP) motor=40*1.342=54A

Is This Answer Correct ?    20 Yes 32 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by vector group

1973


I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok

1182


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

2755


How many kw will suply from one db

1070


How can calculate the rating of a servo stabilizer for given a specific load

3070






what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end

1767


physical identification of HT & LT panel

1207


What’s electric traction?

675


If a air condition consume 2.50 to 3.00 amp then how much it will consume in watts if it is running 10 hours out of 24 hours????

1448


hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx

1479


what can be the causes of capacitor start motor having a higher current that its actual

1506


Explain the operation principle, advantages and disadvantages of the following converters: a) A 12 pulse converter b) A Switch-mode inverter c) A thyristor inverter

1493


1.what is the funtion of chiller primary & scondary pumps. 2.what is the use of distribution lines & Types. 3.what is the use the thermal power stations & how much capacity.

1529


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1674


I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me

1553