Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what r the types of transmission line?

Answer Posted / mayank kaura

Transmission lines are classified according to their span
and working voltage.Usually, the following nomenclature is
adopted to classify lies:
1. Short Lines: Less than 20kV and less than 80km
2. Medium Lines: Lengthe between 80-200km and Voltage
between 20-100kV
3. Large Lines: More than 100kV voltage and more than 200km
span.

Is This Answer Correct ?    118 Yes 20 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the use of current transformer in power transformer secondary side.?its connectyed in WTI

1789


How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.

2842


Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m

2885


What is the types of HT motor testing

3656


Why generation voltage in thermal power plant is between 11kv to 33kv?

1079


What is the meaning of C1, C61, C91 cable

3529


Where is servomechanism used?

1302


how to prepare the technical test

2140


how we can do the insulation on secondary of ct explain and so that tan delta will within limit

1986


IF ANYONE HAVE ANY QUESTION ASK ME AT MY MAIL anmol.bhardwaj5@gmail.com

2146


for opening electrical shop, tips needed.

1894


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2364


1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating

1836


What is the role of feedback in a closed loop control system?

1151


why we are using earth pit in sub stations.?

2227