Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between voltage transformer and
potential transformer?

Answer Posted / biswanath das

Voltage transformer is used for protection of high voltage
distribution transformer. It Compare the primary and
secondary voltage ratio of a transformer and to maintain
fixed voltage at secondary terminal, it sense to auto tap
changer of the transformer to maintain fixed voltage during
no load to full load.
Potential transformer is used for measuring heigh voltage.
It's Primery windings is connected to the high voltage
source & secondary voltage is only 110 volts

Is This Answer Correct ?    71 Yes 35 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What would be the size of wire used for 2 Ton of window A.C?

1909


why sielent pole is used only in hydro generators and not in turbo generators

4184


List few applications of d.c series motor?

1131


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1800


HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT

2002


I want the details about BHEL company examination.Can anyone able to help me please.

2050


How to test the Secure Elite 440 Multi function meter working condition.

2154


What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.

2029


What is electrical diversity factor in electrical installations?

1207


FEINGING DECREASES THE FLUX DENSITY IN THE AIR GAP. HOW?

2187


how does a submersible pump work..?

1963


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2667


state working of halogen lamp?

1819


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1862


what is V.L.F. testing of power cable? do you know the voltage ratings, like for what rating and size of cable what rating of V.L.F. testing is used?

2352