Voltage transformer is used for protection of high voltage
distribution transformer. It Compare the primary and
secondary voltage ratio of a transformer and to maintain
fixed voltage at secondary terminal, it sense to auto tap
changer of the transformer to maintain fixed voltage during
no load to full load.
Potential transformer is used for measuring heigh voltage.
It's Primery windings is connected to the high voltage
source & secondary voltage is only 110 volts
| Is This Answer Correct ? | 71 Yes | 35 No |
Post New Answer View All Answers
What would be the size of wire used for 2 Ton of window A.C?
why sielent pole is used only in hydro generators and not in turbo generators
List few applications of d.c series motor?
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT
I want the details about BHEL company examination.Can anyone able to help me please.
How to test the Secure Elite 440 Multi function meter working condition.
What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.
What is electrical diversity factor in electrical installations?
FEINGING DECREASES THE FLUX DENSITY IN THE AIR GAP. HOW?
how does a submersible pump work..?
AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?
state working of halogen lamp?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what is V.L.F. testing of power cable? do you know the voltage ratings, like for what rating and size of cable what rating of V.L.F. testing is used?