WHAT IS THE DIFFERENCE BETWEEN RESISANTANCE AND IMPEDANCE
IF IMPEDANCE IS MORE THAN RESISTANCE AT SAME VOLTAGE CAN WE
HAVE RELATION DERIEVED BETWEEN THEM
Answer Posted / saurabh
Resistance is a real part of Impedance. Basically Impedance
has two parts a)Resitance b)Reactance in case of
alternating current but in case of direct current it has
only one part that is resistance.We can understand it by
the following eqution:
Z=R+jX (all quantities in vector form)
Where the real part of impedance is R it means voltage and
current are in phase and the imaginary part is reactance X.
Impedance is also define by the equation Z=V/I (all
quantities in vector form)
Reactance occurs due to inductance or capacitance of a
circuit so it has also two types a)capacitive reactance b)
inductive reactance given by the equation, X=ZsinQ.In case
of Inductive reactance the current is 90 deg. lag with the
voltage and 90 deg lead in case of capacitive reactance in
Idea condition. We can also define impedace by impedance
diagram and find out the relation between resistance
reactance & impedance another equation of impedance is
Z=RcosQ where cosQ is the power factor of the system
| Is This Answer Correct ? | 17 Yes | 1 No |
Post New Answer View All Answers
what is meant by neutral compensation factor and where it is used
how can i find ct ratio of meter by seeing name plate of meter and how it should be used in MF calculation if it shows only-/1???
132/6.6ππ πππππππππππ πππππππ πππ πππ πππππ πππ πππππππππ. πΈ'ππ πππππππ πππππππππππ ππ 6.6ππ/415π πππ πΈ πππππππ πππππππ ππ ππππ πππππ πππ ππ ππ 13/6.ππ πππππππππππ?? πΈπ π½π.. ππππ π ππ’??
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?
2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping
Transmission voltage is kept 11KV,33KV,66KV,132KV,220KV due to form factor. What happen to 400KV and 765KV transmission voltage?
WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?
Which capacitor is preferred for high voltage and frequency?
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
how to calculate
How can you sized or estimate the ligthning arrester current rating?
FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?
number of I/O devices in siemense plc
i need previous entrence exam papers of nhpc.