Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why earth hole size is biggest in plug point?

Answer Posted / mahendra

earth hole size is biggest in plug point because, when we
took out the plug from socket the phase & neutral terminals
of socket comes first then the earth contact. Due to safty
purpose Earth contact should be disconnect at the last
moment this prevent any damage to human being and equipment
as well for any abnormal conditions. Another reason for
that is to keeping large contact area for earth because in
fault like earth & short circuit a large current
approximately 6 times flows through circuit.

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1908


redundant connection in contactor?

2547


If the rated speed of a d.c. Shunt motor is1440 r.p.m, which method of speed control would you suggested to obtain a speed of 1500 r.p.m?

1204


why co incidence factor considered in transformer sizing?

1921


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2430


in a simple IDMT relay we use neutral point of ct for earth fault then what is the requirement of neutral ct and cbct?

2219


what is the id1 & id2 setting in differential protection relay of CSPC?

2831


What are the types of piano switches?

2075


When is lag lead compensator is required?

1174


why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)

1958


What is the de rating factor of cable? What is the importance of the de rating factor in cable select

2440


What is the power factor of an alternator at no load?

1385


how to make an earthing certificate

2291


how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.

2027


what is allowable ac mixing in dc

2160