Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is voltage & potential transformer are the same? Are they
used for same application ?

Answer Posted / abhishek kanojia

Yes Potential and Voltage transformer are same and their
use are not only resticted to measuring purpose only but it
is further supplied to relaying panel or to trip circuit so
that the protection purpose and measuring are
simultaneously get satisfied accordingly.

Is This Answer Correct ?    13 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Mention what are the different colors on wires indicates?

1327


we need a ntpc previous papers

1992


which type of cabel

2456


The series field winding has low resistance while the shunt field winding has high resistance. Why?

1770


Ac generato how produce power I need for camplet defination

1829


What is the theoretical reason for the size of a zig zag grounding transformer to be 1.732 times less than that of a wye-delta grounding transformer used for the same application?

2326


for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2153


HI....HOW CAN BE MESARED THE VALVE OF NEUTRAL GROUND RESISTOR WHIC IS LOCATED AT SWICHGEAR ON GENERATOR SIDE....

2144


oltc of a transformer, how it works? and what are the equipment consist of describe briefly?

2068


Why reactors use before incoming of ac vvfd drive?

1909


what is meant by impulse voltage?

2070


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

2010


how single phase preventer works ?

2586


how much UPS neutral erath leakage current.

3815


Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?

2948