Distinguish between the shear center and elastic center.

Answer Posted / Rajesh Tejan

"The shear center (S) is a point in a rigid body where torsional moments act without producing any rotation about that point. The elastic center (E) is a point in a deformable body where the couple produced by two forces would not cause any rotation of the body if the forces were applied at this point. In other words, the shear center is relevant for rigid bodies, while the elastic center is relevant for deformable bodies."n

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

RRB exam model questions pls forward.

2030


Please mail me the Satyam Computers (Mechanical Division, Satyam Technologies, Hyderabad & Bangalore) question papers on Design & strength of materials. Will be very thanksful.....srinivas_1704@yahoo.co.in

2098


hi friends kumar here if anybody of u have essar placement papers than plz send it to me i need it urgently..ok mail id is kskalyani@gmail.com

2027


Dear friends, i am a student of mechanical final year in rajasthan. If you have any type (Technical,interview, aptitude) of question paper related to BIRLA CEMENT LTD. than plz send me these paper at vinodsainikumar4@gmail.com thanks

2133


DEAR SIR, I NEED A MODEL QUESTION PAPER OF JSPL. i'M IN mechanical BRANCH. E-MAIL ID:sksuman289@gmail.com

2261


can any body sand me previous exampapers of jr. engineer (mechanical)

1977


How much stack emmission through your chimney and what is the state govt norms ?

2286


plz send me the aptitude test paper for hpcl.

2100


sir please send previous question papers of technician grade III of all rrb's. thank you

2142


hello, this is sai preparing for mvi exam if any having previous year question papers please help me out

2830


Study the attached ACS 790 AHU and boiler GUI and refer to the video on the software usage, catalog and the step by step document (page 9) to perform the following task: List in a table form the controllers and all their connected I/O for the boiler and the AHU.

1511


RRB exam qustions.

2172


hi, if anyone have previous year paper of NHPC or some questions, Please send me at gupta.pankaj20@gmail.com

2941


Hoew to represent unilateral tolerance, as Bilateral tolerance in engg drawing...? Example: 1.295 +0.000 and -0.10, as unitolerance, write the value in bilateral tolerance?

1994


If anybody have the ref. design book of the 3 point cylindrical rolling with sheet thickness of 2.3 mm & 67 mm internal diameter legth of 80 mm

1896