PLS-00304: cannot compile body of 'string' without its
specification
Answer Posted / guest
Cause: The compiled package specification required to
compile a package body could not be found. Some possible
causes follow: --the package name is misspelled --the
package specification was never compiled --the compiled
package specification is not accessible The package
specification must be compiled before compiling the package
body, and the compiler must have access to the compiled
specification.
Action: Check the spelling of the package name. Compile the
package specification before compiling the package body.
Also, make sure the compiler has access to the compiled
specification.
Please add more information about this Error
Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
NZE-28890: Entrust Login Failed
ORA-26028: index string.string initially in unusable state
IMP-00070: Lob definitions in dump file are inconsistent with database.
Hi guys, I have four tables those are emp,dept,eliminate and uneliminate. i wrote small cursor..when i run, it display one error (ORA-01403 nodata found)... The query is: Declare cursor c1 is select e.ename emp_name from emp e,dept d where e.deptno=d.deptno group by deptno; r1 c1%rowtype; test_emp varchar2(200); begin for r1 in c1 loop begin select eliminate_emp into test_emp from eliminate t,uneliminate ut where t.number=ut.number and t.deptno=e.deptno and rownum<1; end; dbms_output.put_line(r1.emp_name); end loop; end; Thanks...
ORA-26084: direct path context already finished
ORA-26076: cannot set or reset value after direct path structure is allocated
ORA-26094: stream format error: input column overflow
[ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) Unsuccessful: alter table user.CEN_USER_MASTER add constraint FKF4EDEDC3D0BAAE75 foreign key (ROLE_ID) references user.CEN_ROLE_MASTER [ERROR] [main 11:01:20] (JCLLoggerAdapter.java:error:454) ORA-02275: such a referential constraint already exists in the table
ORA-26029: index string.string partition string initially in unusable state
if the lengths of two wires are same and the area of cross sections is 4:7 then what will be the ratio of current passing through these wires
ORA-26079: file "string" is not part of table string.string
IMP-00060: Warning: Skipping table "string"."string" because object type "string"."string" does not exist or has different identifier
IMP-00063: Warning: Skipping table "string"."string" because object type "string"."string" cannot be created or has different identifier
ORA-26082: load of overlapping segments on table string.string is not allowed
ORA-16516: The current state is invalid for the attempted operation.