how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
Answer Posted / Fareed Ahmad
Calibrating a Square Root Flow Transmitter involves several steps, including Range Calibration, Hook-up Series Connection, Zero Check, Pressure Application, and Output Verification. Here's an example of the process using a hypothetical flow transmitter model:
1. Range Calibration: Set the transmitter to measure within its specified range (e.g., 0-150 GPM).
2. Hook-up Series Connection: Connect the transmitter in series with the process piping and pressure gauge, ensuring proper connections according to the manufacturer's instructions.
3. Zero Check: Apply zero flow conditions by closing the upstream valve and verifying that the transmitter output reads its minimum value (e.g., 0mA).
4. Pressure Application: Apply a known pressure to the piping system, allowing the fluid to flow through the transmitter. The output should be proportional to the applied pressure and flow rate.
5. Output Verification: Verify that the transmitter's output is proportional to the applied pressure and flow rate. If the output is not proportional, you may need to recheck your connections, recalibrate the transmitter, or consult the manufacturer for further assistance.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com
any body please send me the old question papers of ongc test.
hi i am eswar i want to know the instrumentation interview questations for eil(engineers india ltd) i have applied for engineer post in eil please help in this.my mail id eswar310@gmail.com
plz send me general of ongc
What is the Working principle of Dozing valve?
this site is owned by an nonsense
DEAR SIR/MADAM MY NAME IS ARKAPROVA BHATTACHARYYA.I AM A FRESHER INSTRUMENTATION ENGINEER.CAN YOU PLEASE SEND SOME QUESTION PAPERS OF GRADUATE ENGINEER TRAINEE EXAM OF DVC(DAMODAR VALLY CORPORATION).MY EMAIL IDs ARE arka_aec@rediffmail.com.
Questions on flow meters,few questions on HART protocol,
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...
Can any one send me IOCL instrumentation question papers.. i dont know the pattern of the questions and what to prepare can any one help me on this .. my email id is anwarnishil@gmail.com
What are the key features of a Distributed Control System? describing the various layers (sensor through to business system interfaces) as well as the hardware, software and security aspects of the DCS.
sir, give me placement papers and interview quistion of birla group company of copper.