Anti-pumping in Electrical Engineering refers to a protective measure used against the flow of current in an undesired direction or backflow, preventing pump stalling due to changes in load conditions.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3881


hi can anyone pls tell me the eee interview core questions asked in l&t

2147


what is the condition for YnD11

2651


CBCT selection

2351


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

1189


How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?

2238


How to calculate the sag on transmission Lines.

3116


Don't you have similar question banks related to Oral Certification Examination conducted by Mercantile Marine Departments / Directorate of Shipping, Ministry of Shipping for Electro Technical Officer?

1764


why lightning arrestor are made in two stack of insulator but why not cvt

2148


where are the circulat the diesel in DG parts name with pictue

2214


hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.

3030


Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.

1055


what will happen if synchronous machine rotor fed from single phase ac supply 

1820


PLZ sent the previous year question paper for GET in NHPC on my EMail id ppshanker@gmail.com

5519


WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.