some time we open engine breaker 8.0 MW load but plant not
trip. and another time engine open 4.0 MW load engine trip
why? individually engine breaker open & individually
emergency stop why difference?

Answer Posted / Jay Prakash Singh

The behavior you described could be due to the settings and trip curves of the electrical system, which are designed to protect it from overloads and faults. Here's an explanation for each scenario:

1. Engine Breaker 8.0 MW load does not trip: In this case, the electrical system may have been operating within its designed capacity or the breaker might be set with a higher trip setting for that specific load level. The system could handle the 8.0 MW load without tripping due to these factors.
2. Engine Breaker 4.0 MW load trips: On the other hand, when the load is reduced to 4.0 MW, it might fall below a critical point in the trip curve or the breaker's sensitivity may be higher for lower loads. This could cause the breaker to trip even though the overall system capacity is still within its limits.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????

2099


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2410


1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends

1909


sir pls send the je exam - 2008 and other model question papers..

2143


i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400

2254


please send me last 5 year interview questions

2280


plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?

2377


ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH

4238


how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)

2059


What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.

2427


What will be result if we connect LT votage to the terminal of HT motor?

2221


How I can Compare 120v/60Hz versus 220v/50Hz ? Please tell me both advantage and disadvantage ......

2105


sir i want previous entrance exam papers for written test

2242


hi this is hema, r there any books in particular for the preparation of the APPSC-A.E.E(electrical), if so please mail me the names ... thank u .

2001


PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com

2101