what is the analog input , analog output , digital output,
digital input geven to the MSSV , CBD, IBD , START UP VENT
, BOILER FEED PUMP , AOP, CEP , ETC
Answer Posted / prabhakaran
AI-TRANSMITTER
AO-CONTROL VALVE
DI-LIMITSWITCHES
DO-SOV
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how pressurize drum calibrated ?
what is the difference between -24 : +24 & 0:24 and where it use?
What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
I have 0.75mm sq multicore cable (IS type) , can use instead of same type but 1.5 sq mm cable ? Note : The distance is around about 150 meter.
Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.
what is easiest way to read STL language in PLC?
use of split range ? where it is used ? in which control loop it is used ?
pls give me presant awerness quistion and answer in my emailid.
Please any one can provide latest aptitude test,technical test and interview questions for tata consulting engineering (TCE) i need it asap thanks in advance
can any one tell me when ongc placement test and its forms is available????/ pls tell me if u know
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
why we us isolation barrier in hazardous area how it works to protect the area and please clarify its current flow.
Explain the key components of control loop?
what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??