what r the preventive maintenance of air compressor
Answer Posted / vishnu vardhan reddy
Star delta starter used for air compressor, feeder side check all connections tight the loose connections check fuses,check contactors blades cleaning,check olr ,blowering feeder,motor side TB checking, Megger the motor, blower the air filter,check the junction box
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the difference between electrical earthing and electrical grounding?
how to calculate the magnetizing current of ct ( 800A/1A) for Relay 64
how to make an earthing certificate
A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3
when will be the iocl interview results ifaced the interview on september 8 th
what is is the potential diffrence between two phase ?
1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done
what is there inside an inverter and how it works?
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
how to find the torque of the single phase synchronous motor by doing an experiment
Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
what is physical distance of isolator to VCB in 33/11kv sub stations
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer