is plate load test can be done on cohesive soils for immediate settlements ?
Answer Posted / rajasekar
Ans is yes, Because cohesive soil commonly has less density. So we should do plate load test before Start the high-rise building.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is civil all interview questions
As per Kandal suggestions, we have implemented rolling starts on 140 (+/- 5) degrees and we kept 3 rollars to complete the rolling before falling 125 degrees and the Aggregate AIV is below 22. But When the DBM bed is being rolled 3rd high viabration, (Before 1 plain & low ,2 high Viabrations), the aggregate is getting sharp edge agg. projections are damaged. As the literature is said that, the VG-30 Grade having better control the temp. susceptibility than Penetration grade. if so we could not get this problem at site. But we are facing on site. let me know.
procedure for preliminary selection of size of column of 5 storey building
what are the types of dimensioning?
what is the quantity of block work required to construct a compound wall of 6" thick,and 212 lenght
How to do base isolation using ETABS software?
List out some of the common problems that architect have to tackle it?
i want texture painting pwd data
undistributed samples are obtained by
which steel is better for residential building tmt steel or hysd steel
how do we design mix ratio?
As in practice, we are deducting every 2d for 90 degree bend but from where it comes means derivation or reference of IS Code.
i) Distinguish between Theodolite and dumpy Level? (Marks-8) ii)Distinguish between Viscous and Turbulent flow? (Marks-8) iii) Distinguish between nominal and design mix? iv) What is standard sand? v) Explain the term plane stress? Vi) Differentiate between principal plane and principal axis? Vii) write short notes on Elastic limit of structural steel? viii) Write short notes on stress concentration? ix) write short notes on "Grading of Sand" ? x) How many grades of concrete are there under standard concrete?
What is the unit standard weight,thicknessof C.I>Pipe of various Dia upto200 MM(as per IS1538)
I used Etabs software to analyse a high-rise building. And I want to use templated UBC-codes inside to calculate the Seismic load. My question is: whether or not I have to control the seismic load by base shear load which is manual calculation? (just for more clarification: I can control this by input the scale factor into Eartquake definition in Etabs) I would highly appreciate your answer.