ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.13 : (i) In the Present Value Multiplication Rule, let PV = present value, Ra = interest rate for first discount, A = duration for first discount; Rc = interest rate for second discount, C = duration for second discount. Let PV = [ 1 / (1 + Ra) ^ A ] [ 1 / (1 + Rc) ^ C ] where ^ is the symbol of power : 3 ^ 2 = 3 x 3, 2 ^ 3 = 2 x 2 x 2. (a) For discounts involving 8 % / year for 3 years and 10 % / year for 9 years, find the value of PV. (b) If Re = interest rate for third discount, E = duration of third discount, form a mathematical equation of PV as a function of A, C, E, Ra, Rc, Re. Note : Discounts are available in the purchase of certain biochemical engineering instruments. (ii) Let R = nominal interest rate related to growth rate of money, r = real interest rate related to growth rate of purchase power. If I = inflation, where the unit of R, r and I is %, find the mathematical relatonship of r as a function of R and I.
Answer Posted / kangchuentat
ACCOUNTING AND FINANCIAL ENGINEERING - ANSWER 34.13 : (i) (a) Let Ra = 0.08, A = 3; Rc = 0.1, C = 9. Then PV = [ 1 / (1 + Ra) ^ A ] [ 1 / (1 + Rc) ^ C ] = [ 1 / (1 + 0.08) ^ 3 ] [ 1 / (1 + 0.1) ^ 9 ] = 0.33666. (b) PV = [ 1 / (1 + Ra) ^ A ] [ 1 / (1 + Rc) ^ C ] [ 1 / (1 + Re) ^ E ]. (ii) r = R - I. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
based on percentage problems
How can wet carbon dioxide be responsible for a corrosion problem in iron-containing metals?
What is a cstr and what are its basic assumptions?
In case of welded vessels why is stress relieving in the form of post-weld treatment necessary?
Explain the functioning of a three-way catalytic converter.
Plz if anybody has placement paper of HAL mail me i m Chemical engg my id er.kotnala@gmail.com
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
marketing procedure of iocl
send previousyear question paper for ongc gt 2011 chemical engineering written exam
Define octane number?
In Pressure Sfety Valve(PSV) 2" by pass line why given for process units.
which materials can l use if l want to use length wave 680 to 900 in hplc
Explain what information is needed to specify a mixer?
Is there a quick rule-of-thumb to estimate a gas side heat-transfer rate inside the tubes of a shell and tube heat exchanger?
Explain the factors involved in designing kettle type reboiler?