Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

PRV (Pressure relief valve) Trip with oil splash outside power transformers

Answer Posted / ali

Hi ,

My 50/60MVA ONAN/ONAF power transformers tripped at 47MW power , but no windding temp alarm or trip , no any other indication, just PRV trip, what is the reason ?

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If a air condition consume 2.50 to 3.00 amp then how much it will consume in watts if it is running 10 hours out of 24 hours????

1861


what is the condition for YnD11

2549


why the neutral line is not giving shock to us if we touch it ?

1773


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1956


how to protect motor in dol starter having capacity of 30 hp.40 hp?

3205


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2201


Why is a synchronous motor always star connected??

2600


Transformer diagram mention each parts ?

2034


Why do we require transformer with less specific weight if supply frequency is increased?

1575


why HT armoured cable does not glanding

4227


what r PID controllers?why they r used?what is there purpose?plz Explain in detail

2068


What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker

2006


What is purpose of reactor?.What is different between line and bus reactor?

1939


we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.

2001


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

2361