Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the no.of slots in stator in not equal to the no. of
stator in rotor in induction motor????

Answer Posted / gundra chakrababu

if the stator and rotor have same umber of poles,the harmonics produced in them are also of the same order.as these harmonics slip past each other, pulsating torques are produced,if the speed of these harmonics coincide,the stator & rotor poles would lock each other.this condition is called "cogging".under this condition,the motor would crawl at a subsynchronous speed and develops a synchronous torque.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How servo stabilizer works.

2113


how can calculation ate Amps for cabel. Ex-for 1sqmm wire hou many amps we can draw

2448


I am interested to know what does 15 KVA DG set actually means? If I dont know the DG rating, is it possible to identify KW by simply knowing the diesel consumption?

2159


WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.

2138


What are the applications of autotransformers?

1076


Can we Co-ordinate relay in Load Break switch?

1957


what is mean by transition resistance of transformer?

4532


how to generator maintenance (A Check, B check,Etc)

2292


why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)

1895


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1711


Why negative feedback is preferred in the control system?

1254


10 tube light connect in mcb breaker.one tube light is fault.so breaker is tribe.how fault is rectified.(using 3wire phase,earth,neutral)

2671


can some one clearly explain why -48 volt DC use in telecom site????

1679


DC transmission

2063


What are the advantages of autotransformer?

1212