1. what is 3 point calibration & 5 point calibration?
2. If we use hart communicator to set the LRV & URV of a
smart transmitter, did we calibrate the transmitter? why?
3. Make a complet list if meterials needed to properly
connect a pressure gauge to a steam pipe using 1/2 inch
stainless steel tubing. The gauge connections is 1/2 inch
NPT-M and the steam pipe tap has a 1/2 inch female coupling,
compression fittings are use.
4. What are the tools in loop checking?
5. What would the ISA symbol of a square root extractor look
like?
6. What would you do to completely prepare for the
configuration?
7. What safety measures must you undertake when doing
configuration?
8. what are the two most commonly use programming languages
used when we configure a PLC?
9. What would you do if you accidentally skipped a step in
the configuration procedure?
10. How would you know if the configuration were sucessful?
11. Name at least 3 selections available when we configure
the burnout protection of a controller?
Answer Posted / bhoorzky
In bench calibration,what is the function of a resistor
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
what is effect of specific gravity in differential level transmitter , explain formula related with this .
What is 3 element control system
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
how to rectify the poor signal strength in utrasonic digtial flow meter ,model:ge digital xce868i
what can of fault ofently come in vibration mesurement?
Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram
With N nodes and B branches what will have a network ???
Hook up resistance decade box to temp.transmitter.
why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??
How an rtd work, and what volts/current goes to a rtd to measure the resistance?
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
what is span value and zero ? and how set ?
How INtools is useful for routine Instrument maintenance?
What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.