Answer Posted / faiyaz
Level sensor
Pressure sensor
Temperature sensor
Flow sensor
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
flow transmitter formula?
Do you have reference list?
What are the types of control valves available
what does it mean an active front end in vfd plz explain it briefly
What is Span Error
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
how to design orifice plate?what is the equation?
What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller
HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?
How do bending tubing provide better measurement than using tubing fittings such as elbows?
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?