In my plant I want to mount a steam flow transmitter .Flow nozzel is already mounted in steam line .So how can i know the range to put in flow transmitter?
Answer Posted / varatha
should ask for the data sheet
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How ejector(or)evactor air pump is working in thermal power plant?
Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com
Decibel.
Why grounding is necessary? Give example with diagram.
how to calibrate 0- 150 psi presure gauge by dead weght tester
what is controlling card in dcs? how u measure dcs memory?what is bus in dcs?how u know dcs speed n ehternet speed?
What is three element drum level control system why its better than single element?
how will you segregate the alarm levels in alarm management system during factory Acceptance Test
what is the calibration procedure for transweigh make weigh feeder?
hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747
protection relay watchdog contact operation?
what is zero and span ?
draw the block diagram of a level transmitter ?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card