what is the difference between id fans and fd
fans
Answer Posted / mrigendra pratap singh
ID fan(Induced Draft Fan)basically pulls out flue gas from
the furnace of boiler. It is located between dust
precipitators(ESPs) and Chimney. Obviously it handles hot
air/dust. Whereas, FD fan(Forced Draft Fan)supplies the
required air into the furnace for combustion of fuel. It
handles air at normal temperature. The capacity/power
rating of ID fan will be more than that of FD fan
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is 11 N1 and 12 N2 in single phase Transformer ?
What is the difference between the relay and the circuit breaker?
What is the formulae of Megger value for a A.C.Motor
what is the function of anti pumping relays? what is KVAR? How it is generated in alternator? What is 3rd Harmonics? What is IDMT relay?
What is steady state response?
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
What are the basic properties of signal flow graph?
list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.
what shoud be strength and weakness to impress interviewer????????
What is the current carrying capacity of 35sq.mm flexible cable?
what is the use of the puls transformer in UPS & how it works???????????
why Lightning arrestor are made by 2 seperate stack of inslutor but why cvt are in single stack of insulator.
What is difference between Harmonic and Non harmonic Capacitor Bank?
Why ground terminal is used in pot meter 10k ohms
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?