Answer Posted / tapiwanashe vhurumuku
service factor is the measure of periodically overload capacity at which a motor can operate without damage
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Which type of DG need Netral Earthing?
how is the connection of a 3 phase ct trivector meter done on a pole mounted transformer
i need mat lab program to find out the transmission line losses,regulation and losses
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
what is reactive power?, why its measured in VA ? is it transient behavior of system?
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation
What is real time power factor control panel(RTPFC)?
What is the dependency of stiffness on load angle??
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
Best way to measure the Soil resistance of rocky soil, three probe method and four probe method
how can i change the rotation of the AC single phase induction motor and show me by diagram
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?