QUANTUM CHEMISTRY AND CHEMICAL ENGINEERING - EXAMPLE 31.4 : In a rigid rotor model in quantum chemistry, the moment of inertia I is given by an Equation E as I = Ma x La x La + Mc x Lc x Lc = m x L x L, where m = (Ma x Mc) / (Ma + Mc) and L = La + Lc, m is the reduced mass, Ma is the mass of a, Mc is the mass of c, La is the radius of a from point O, Lc is the radius of c from point O. Prove by simplest method that Equation E is wrong.
Answer Posted / kangchuentat
QUANTUM CHEMISTRY AND CHEMICAL ENGINEERING - ANSWER 31.4 : Let Ma = 0 and Mc = 1 as assumption. Substitute them into Equation E as I = Ma x La x La + Mc x Lc x Lc = 0 + Lc x Lc = Lc x Lc. However, m = (0 x 1) / (0 + 1) = 0, then I = Lc x Lc, which is not equal to 0 but I = m x L x L = 0 x L x L = 0. Equation E is proven wrong. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Hi, I am Gurunathan. I am in need of ONGC, IOCL, DRDO technical test ( chemical engineering)and general aptitude questions. If anyone has kindly post it to me soon.
What is maximum recommended velocity for steam in a plant pipe network?
Explain some good strategies for curing tube vibration in shell and tube exchangers?
What is the process of including heat exchangers in ammonia refrigeration system?
Are there any methods of preventing cracking of carbon steel welds in refining environments?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
What are the various utilities of the process plant?
Explain the procedure to estimate the friction factor involved in heat exchanger tubes?
Are there any special considerations to be taken into account for combusting ammonia?
which accomplishments in your present position are you proud of and why?
What are the frequently asked technical questions in chemical engineering during PI?
How can you estimate a gas flow based on two pressure measurements?
how will we calculate the heat of formation through electron...??
Name the some common problems associated with bellow expansion joints?
Define pcbs?