what will happen when a electric bulb is connected between
two phases.it will glow or not
Answer Posted / satadal
Actually this is dependent on phase voltage and lamp rating voltage. In India the supply voltage is 440 V,50 Hz. for 3 phase.
and normally we will get 220 V at single phase with neutral
& 420V with Phase to Phase.
if our Bulb is rated for 240 V and we connected between two phase, the bulb get fuse due high volage.
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
what is the difference between dry and wet type of 132kV terminations. which one is durable
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
Why squirrel cage motor can only use with low starting loads ?
Difference between megger test equipment and contact resistance meter test instruments?
132/66kv sub-station procation ?
how solar power plant energy meter multiplication factor
what is meant by vector group of a transformer? How can it be derived?
What will be the current drawn by HT motor, if low voltage is applied.. any formula to calculate the LT amps of HT motor.?
Explain and give examples about VCB?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
i have interview in Pepsi company what type of question will ask please send the question and answeer
what is rocking arrangement in arc heating
State angle criterion.
what is meant by IGBT how they differ from tyristor ?