What is Difference between Bench Set & Operating Range of
Control Valve?

Answer Posted / praveen kumar

bench set is called based on the line pressure, control valve actuator spring adjustment....if control valve spring range 0.4-1.0 bar means ..the control valve will start to opened at 0.4bar instrument air pressure.before or after 0.4bar it should not start to open, at 1.0 bar the valve should be fully open(max travelling range of valve)...
Operating range is called as positioner output 0.2 to 1.0 bar...

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is defferent betwen ESP &PCP PUMP .HOW IT IS WORK?

2027


hi my name is rakesh patel i just complited my be in instrumentation & control now i am going to working as a validation engineer in a poject department so what is a scope in a future as a validation engginer ? what line is good for me can any bady give me complete solution please? your regard rakesh patel

1516


Describe a time when you anticipated potential problems and developed preventive measures.

2481


How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?

1578


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

3433






Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

1636


Explain about safety integrated level protection? . How it was differ from other protections ?

1254


Q- What are the application in which PNP transistor is preferred over NPN ?

2838


WHAT IS THE CAM POSITION IN CONTROL VALVE POSITIONER ? WHY IT IS USED?

546


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

1710


How hart protocol can be connected with control valves?

602


Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264

1509


can u briefly explain aboutan aryton shunt multirange DC ammeter?

2299


Difference between 2-Valve Manifolds, 3-Valve Manifolds and 5-Valve Manifolds 3 with diagram

2684


Explain how thw analog to digital converter works with the circuit diagram

2176