Answer Posted / aris
There is a lot of confusion when it comes to “flameproof” products. Ex d or “Flameproof” means that an enclosure or junction box is constructed and certified as Explosion Protected according to the “Flameproof” standard. The “Flameproof” philosophy is that should an explosion occur within the enclosure, it will either be contained or the escaping flame will be cooled by a “flame-path” thus mitigating the risk of igniting an explosive outside atmosphere. Other equipment designated flameproof, like a flameproof cable gland, is constructed in such a way that it will maintain the flameproof integrity of a flameproof enclosure to which it is fitted. Ex e, on the other hand, means that the enclosure is constructed and certified as “Explosion Protected” according to the “Increased Safety” standard. The philosophy with Ex e is to provide an impact resistant enclosure and also to ensure that its contents are certified such that they will never produce sparks or temperatures or current creepage that could ignite the flammable atmosphere which may enter the enclosure. Ex e rated enclosures are therefore explosion protected but are not “Flameproof”. In selecting both Ex d or Ex e equipment it is necessary to ensure the Temperature “T”-rating and the gas group certification is appropriate for the specific prevailing flammable atmosphere. Both Ex e and Ex d junction boxes can be used on Zone 1 areas. Ex d Flameproof boxes are normally manufactured from heavy patterned cast iron and are generally also suitable for use underground in coal mines. Ex e Increased Safety boxes are normally manufactured from an engineered plastic and are generally suitable for surface applications and in non-fiery mines. Ex e is usually a less expensive method of protection than Ex d. We are always here to help or give advice if you are not sure
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
what is the difference b/w absolute encoder and incremental encoder?
how to select correct size of power cable for inverter duty motor
why are u join ntpc
WHAT IS THE DIFFERENCE BETWEEN AN ACB & mccb 7 WHAT IS THE CRITERIA WHEN TO USE WHICH OF THE TWO
How efficiency of thermal plant can be improved?
what is the difference between fault current ant short circuit current?
Why synchronous motor is used in power factor improvement,dc series in lift
What does the term power factor shows?
What do you understand by avr?
1) What are your personal strength? 2) What are your personal areas of improvement? 3) What are your expectations from from a particular job? 4) what are your carrier objectives?
PLS MENTION QUESTIONS ASKED IN IOCL INTERVIEW FOR ELECTRICAL EGG??
Pl.brief me about Electrical power distribution system from Main generating station to Industry.What is the use of in between station.
Is it possible to implement Restricted Earth Fault protection for a transformer without neutral CT?
How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?