THERMODYNAMIC - EXAMPLE 10.3 : According to Raoult's law, the pressure when vapor is completely condensed, P = x(1) P(1) + x(2) P(2) ... + x(n) P(n) when x(1), x(2) ... x(n) are the mole fractions of component 1, 2 ... n and P(1), P(2) ... P(n) are the vapor pressures of component 1, 2 ... n. A vapor at 74 degree Celsius containing 70 mole % water and 30 mole % ethanol is to be completely condensed. At the temperature of 74 degree Celsius vapor pressure is 0.38 atm for water and 0.97 atm for ethanol. What is the minimum pressure the compressor must be operated?
Answer Posted / kangchuentat
THERMODYNAMIC - ANSWER 10.3 : Let component 1 is water, component 2 is ethanol, x(1) = 70 / 100 = 0.7, x(2) = 30 / 100 = 0.3, P(1) = 0.38 atm, P(2) = 0.97 atm, then P = x(1) P(1) + x(2) P(2) = 0.7 (0.38) + 0.3 (0.97) = 0.557 atm. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
I HAVE DOMAIN KNOWLEDGE IN PROCESS MANUFACTURINGAND I GOT AN APPARTUNITY AS A BUSINESS ANALYST AND I DNT HAVE ANY KNOWLEDGE ON ORACLE APPS/GIVE ME ANY VALUBLE SUGGESTION?
What is the process of including heat exchangers in ammonia refrigeration system?
Explain the different characteristics that can affect the flow of bulk solids and how?
What are the greenhouse gases in earth's atmosphere?
Define a solvent?
What is a good method of minimizing shell side pressure drop in a shell and tube exchanger?
Define pcbs?
Hi, I want to validate an analytical procedure of a specified impurity, but this impurity is unavailable for me. can I use the API instead of impurity in the linearity test? in Which reference can I find such information?
send previousyear question paper for ongc gt 2011 chemical engineering written exam
How to size the cooling tower sump / basin for any given circulation rate? What is the guideline?
What is fuel requirement of 20kg/hr of incineration having material calorific value 6500 kcal/kg and diesel calorific value 10707 Kcal/Kg (PCC=850 degC and SCC 1050 Deg c)
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
testing formula for oxygen by ammonium chloride,ammonium hydroxide and copper
How fouling effected the heat transfer rate?
What are the design considerations for a piping system for the transfer of slurries?