what is difference between DO and DI

Answer Posted / faiyaz ahmad

DO-Digital out put its used to control the ESD system PSD system means ESD valve and PSD valve which one control through the DCS that is called Digital out put which signal coming from in DCS like proximity switch limit switch and proximity sensor means its on/off it is called Digital in put.and all the transmitter is analog input like pressure transmitter level transmitter flow transmitter and temperature transmitter and all the fire and gas system is analog input and 4 to 20 mA signal is analog out put like control valve

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is loop1 and loop2 in MTS LT?

4188


hello can yoy pls send me previous papers of jindalpower and steel ltd.....'m from instrumentation..... mani1048@gmail.com

1583


Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?

1055


how to calculate the total flow in square root

1744


How will you test a transistor with a multimeter?

626






whats the abbreviation of IOP? is it instrument of power or input open problem?

662


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

1247


what is interlock system and why we use of this?

1445


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

1730


How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?

2515


what is droop in governer ,type of droop ,how it work

1763


why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?

1757


What are the uses of orifice plates?

617


control panel design guidelines

2858


State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.

1540