iii) A shunt motor runs at 70 rad/sec from a 460V
supply and takes in an armature current of 100A. Resistors
of 2.52 ohms and 1.64 ohms are connected in series with the
armature and in parallel with the armature respectively.
The field excitation remains direct from the 460V supply
but the generated torque is halved. Determine the new
running speed. Neglect brush voltage drop. The armature
resistance is 0.4 ohms.
[15]
Answer Posted / ajay kumar
44rad/sec
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What are the different types of transformers?
why it is so called as xlpe(cross linked poly ethyline) cable?
How to know the Max. current caring capacity of the cable by its size ?
Which level of the Transformer oil got dielectric strengh? And why?
Is it possible to download the Siemens Selection Chart(TYPE 2 coordination) for 1) fuseless selection 2)Fuse selection
Briefly define and explain the following different types of Pulse Amplitude Modulation (PAM) with some examples. i) 2-PAM ii) 4-PAM iii) 8-PAM iv) 16-PAM v) Quadrature Amplitude Modulation (QAM)
sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
what happen as when voltage drop(or may decrease) ? in case of atomic base theory?
how to build a network which step down 415v to 1v rms
If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?
WHAT IS VCB SAFETY
1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor
why we can use 1 to 5V dc
Hi, My plant daily consumption is calculated as 3.8MWH but my supplier has sanctioned an power of 2.6MW per day. how can i equal or distinguish this two factors