How can get electrical c licence.Now i am working in spining
Mill , transformer capacity 2750kva. Sanction demand 2250kva.
Please advise me . My contact no 09944226823
Answer Posted / vadlamudi068
dear sir ..
I completed diploma in electronics and communication engineering.how can get electrical c licence.now i am working in NTTF collage in electrical maintenance..please tell me about this..
| Is This Answer Correct ? | 2 Yes | 6 No |
Post New Answer View All Answers
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
What is trip and closing coil in cb? Why need of them
why normally Generator rating are between 11Kv to 22Kv?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
Define non-touching loop.
How REF protects transformer alone? explain with diagram.
what work will do diffrential realay DG set
Any one who apply for Ferro Scrap Nigam Limited cn join with me at rajuhalder@indiatimes.com or 09669717028
what is meant by IGBT how they differ from tyristor ?
Define settling time.
Is there any specialised book to refer about fault level calculation both in MV and LV side??
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
Tell me the reason of connecting domestic t/f primary in star or delta,and also secondary side.