Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the purpose of a process loop? What is the
controllers responsibily?

Answer Posted / jadhavamit

The above question answer is explained by an example-
suppose we have to control the temperature of the water from "Heat Exchanger", for these we required a following instruments-
Temperature Transmitter=The transmitter sense the temperature of the boiler and convert these signal to standard signal 4-20 mAh.
Temperature Indicator and controller= The indicator use in the process has a facility of setting a SP(set point) for the desire process, these indicator with its inbuilt technology find out weather to increase the flow of steam or decrease the flow of steam. these condition depend on the logic E(error)=SP(set point)-PV(process variable).

suppose the output water has to maintain the temperature 200 degree cent. these is the SP to the controller.The controller will receive the signal from the temperature transmitter which is process variable(PV) and compare it with the SP i.e. let x be the PV(process value) then,
E=SP-PV
E=200-x
let x=150
then E=200-150
E=50
the value indicate that the inlet flow of the water should be OFF so that the outlet water temperature will reach to SP.

Note- Positive value OFF the inlet flow.
Negative value ON the inlet flow.

Temperature converter(I to P converter)= The signal send by the controller logically is converted into pneumatic by I to P converter with standard signal 3-15psi.
i.e. 3psi =4mAh &
15psi=20mAh respectively.

Valve= The valve can be air to open or air to close depend on the site selection and safety aspect.

*The controller responsibility is to maintain the process in SP and take the proper decision.
*Beside these was short or easy process so we can control it manually but when there is a large process parameter or it is not possible for a human to pay attention or also in hazardous area then at these place the controller play a vital roll in industries.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

2103


I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.

2202


how to set relay setting? and example calculation...

2087


What is the application of Dyn1 and Dyn11 vector group of transformer?

2935


if i am in front of transmission line how to know that current direction without any equipment

1837


what is feeder bay?

1650


how load of a turbo generator can be increased

2015


how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???

1977


from which subjects most of the technical que will b asked for hpcl(electrical).pls help me

2056


what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?

4114


What is tranformer differtial?

2090


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2941


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2154


how to calculate earth fault relay current and CBCT ratio

8400


Whether power factor should be high or low? Why?

1178