why high pressure heater will take after sufficient pressure?
what happen when high pressure heater will take from COLD
REHEAT line at light up time when hp and lp by pass in
service.(means can we heater take at low pressure?)
Answer Posted / chetan h malaviya
We can take CRH extraction line(HPH 6) in line during lit up but at that time pressure of CRH line must be >5 kg/cm2 and corresponding degree of super heating must be >100 'C
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
By any way can we increase the B check hours from 300 to 500
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
procedure of how to generate power in solar plant.
can dp type level transmitter work in under vaccum condition
explain how the third harmonic content of the magnetising current affects transformer design
what does mean by kva rating
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
LAPT working in alternator / generator
How We Calibrate the vaccum transmitter?
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
Why superheated are started before I'd and rd fan?
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?