why the transformer was not rotating like a motor?
Answer Posted / n.a. abbu
Rotation or motion required only to cut magnetic lines nearby coils or windings. But in transformer case we are using A.C. supply to transfer power from one circuit to other circuit. We know in A.c both magnitude and direction changing by nature. Therefore no need of any motion or rotation to cut magnetic lines to induce e.m.f in nearby coils say secondary.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV
what is basic difference betmeen normal & flame proof motor??
What is slip in an induction motor?
How does a television work?
what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
What does a Bode plot tell you?
how is the incoming cable size calculated for a given current rating of a panel??
Could u pls tell me the NPCIL electrical engineering interview questions for Executive trainee, and also guide me how to face the interview.
why we cannot protect 100% winding of an alternator by using differential protection?
How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
How can find thermal state value in relay for calculate thermal overload.
What is an Air COmpressor