What are difference between automatic and manual control system?
Answer Posted / uday
Human operated system is called manual control system.like speed control of vehicles.it's operation based on human sense.
Automatic control system have sensor mechanism, sense the actual condition and send feedback to controller.
| Is This Answer Correct ? | 6 Yes | 3 No |
Post New Answer View All Answers
why fuse block is not used for AI signal?
Explain the burnout feature.
What are the different types of thermistors used in industries? How to the operation of typical thermistor?
What are the interlocks we have to check during the start up of LP/HP compressor?
I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?
How to find out the current of two motors having same power consumption but different RPM?
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
What is standard procedure of manual mapping in Radar type level transmitter?
why would you like to join our company
why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?
what are the diff. in servo and regulatory control?
how many types of spped sensors n vibration sensors?their basic principle n connection?