how to define the P,I,D value in tuning pid loops in online.
Answer Posted / morsli
HI ,you have to do on first time the derivative action Td at 0 value to eliminanate a derivative action Td =0 and the integral action at maximun means 1/ti=1/maximun =0 and you have to adjust the propotional band to minimun value till you have cycling ,and if u have cycling you adjust the proportional band to twice of cycling value ,you fix the of the proportional band then you adjust integral band same as the proportional ,you decrease the reset value till you have cycling and then you multiply this value on twice ,and you set this integral operational value
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,
what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.
Tr. Wiring for calibration.
the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)
How to control flow variations in magnetic flow maters..... When i will provide proper earthing?
can u briefly explain aboutan aryton shunt multirange DC ammeter?
Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system
In Safe Guarding test what means by "Failed to Danger" ?
What is the purpose of the analyzer in petrochemical plant?
What is Cavitation in a control valve?
䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ
what is the input of digital counter during the the calibration time?
What is the difference between ff transmitter and non ff transmitter