how starting current in motor is reduced in case of motor in star connection.

Answer Posted / rishad

In a star connection Line Current is Equal to Phase Current. i.e.

Line Current = Phase Current

IL = IPH

Where as in delta line current= 1.732 phase current

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why r u using pf panel. what the uses

1496


Can I use distributon class/transmission class Lightning arresots for protecting the building? If not why please explain?

1415


hi friends how 3 phase converter functioning ?what is working principle of rotory phase converter ?

1614


Currently what is the highest capacity (MVA) of SPPg generator available in the market?

1325


Difference between Lugs and Thimbles

13734






how does commutator convert a.c to d.c?

1760


v/f drive basic princeple

1993


if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?

993


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1130


In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.

1275


1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?

1369


I AM GOING TO ATTEND APTRANSCO ON 26TH OCT 08.PLEASE SEND ME ANY MATERIAL OR TYPE OF QUESTIONS OR EXP QUESTIONS.

1506


Which type of DG need Netral Earthing?

4493


12.5 tons a/c is their how much kva generator can recommend to the customer.

1476


1. The DC generaror,s induced output emf is connected with a DC motor(as load). when increasing the load of the motor by using brake drum or any way. what are the parameters will changes in both motor and generator(voltage, current, resistance, frequency, speed, torque, power, flux etc...) 2. Similarly for AC generator and AC motor 3. similarly if using DC batteries instead of DC generator, What happens?

1684