Question 55 - The differential equation is 3 dy / dt + 2y = 1 with y(0) = 1. (a) The Laplace transformation, L for given terms are : L (dy / dt) = sY(s) - y(0), L(y) = Y(s), L(1) = 1 / s. Use such transformation to find Y(s). (b) The initial value theorem states that : When t approaches 0 for a function of y(t), it is equal to a function of sY(s) when s approaches infinity. Use the initial value theorem as a check to the answer found in part (a).
Answer Posted / kang chuen tat (malaysia - pen
Answer 55 - (a) For the equation 3 dy / dt + 2y = 1, its Laplace transformation is 3 [ sY(s) - y(0) ] + 2Y(s) = 1 / s, 3 (sY - 1) + 2Y = 1 / s, 3sY - 3 + 2Y = 1 / s, 3sY + 2Y = 1 / s + 3, Y (3s + 2) = (1 + 3s) / s. Y = Y(s) = (1 + 3s) / [ s (3s + 2) ]. (b) Initial value theorem states that y(0) = sY(infinity), then 1 = s (1 + 3s) / [ s (3s + 2) ] = (1 + 3s) / (3s + 2) approaches 1 when the value of s approaches infinity. The checking is correct. The answer is given by Kang Chuen Tat; PO Box 6263, Dandenong, Victoria VIC 3175, Australia; SMS +61405421706; chuentat@hotmail.com; http://kangchuentat.wordpress.com.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Why does catalytic converter used in an automobile?
What are advantages using hollow shaft impeller?
What are the advantages of using gear pumps?
What are demand of crotonaldehyde99% in the worldand its international market ?
How does a cyclone separator work?
What are some common problems associated with dilute phase pneumatic conveying?
What are the different types of equipments for the conveyance of solids?
List the advantages and disadvantages of a pfr?
What is a surfactant?
Explain how can you estimate a gas flow based on two pressure measurements?
i want sample inteview question of chemical engg for BARC
what is first order of reaction?
testing formula for oxygen by ammonium chloride,ammonium hydroxide and copper
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)