how to calculate no. of bricks for 1 cft?
how to calculate cement and sand in cft?
Answer Posted / nadim shaikh
take brickwork as 100 percent then deduct the mortar
for e.g
6 " wall dimension 10' x 10'
10 feet divided by numbers of mortar layer which will be decided by dividing it by brick laying format for stretcher bond it will be
10' / .33 (4 inch = .33[4/12])
=30 numbers + 1 = 31 ( this was for vertical )
now for horizontal
10'/.75 = 13+1 = 14 joints
now
10' x .5 x .08 ( dimesion of mortar laid in horizontal direction) = 0.4 x 31 joints = 12.4 cu.ft
&
10' x .33 x .08 ( dimension of mortar laid in vertical direction) =0.264 x 14 joints = 3.7
add both i.e 12.4 + 3.7 = 16.1 cu.ft
if 10' x 10' x 6" = 50 cu.ft is 100 % the how much percent will be 16.1 of 50 cu.ft ..
16.1/50x100 = 32.2 say 33%
wooah .. that was quite a lecture
| Is This Answer Correct ? | 10 Yes | 2 No |
Post New Answer View All Answers
what are the cube & Sylinder strength of concret M20,M25,M30,M35,M40,M60 ,M75,M10 ,M15
What is the quantity of cement used for stone pitching work of 100sqm 225mm thick and cement mortar of 1:6? And how?
How will you reduce the concrete flow after mixing the concrete
With reference to construction of state highways, please let me know the total Bill Of Quantities as per the following details:- 1) Subgrade - 500 mm 2) Granular Sub-Base (GSB) - 200 mm 3) Wet Mix Macadam I (WMM I) - 150 mm 4) Wet Mix Macadam II (WMM II) - 100 mm 5) Dense Bituminous Macadam (DBM) - 60 mm 6) Bituminous Crust (BC) - 40 mm Road Length is 44 Kms. Road Width is 7 mtrs. Please provide the BOQ of each layer as per Compacted Factor & Loose Factor both. Also, if possible please provide me the approximate details of total material required (all categories viz. soil, gravel, stone aggregrate, sand, bitumen etc.) as per general mix design prevailing in India. Thanks & Regards -- Rokr
what quantities of work done in terms of sq.mts/day/ of 8hrs for each varpenter (shuttering) and Steel fitter in terms of Tonnes. For slabs, Columns etc.?
how much area can be platered by a mason for exterior
why does the most of civil engg is not intersted to going for teaching field?
how to calculate the concrete mix m30 by volume
Need help in designing a degasser tower for 2m3/hr DM plant, also send me the formulae used
std penetration resistance in very stiff clays lies bet 2 & 4 4 & 8 8 & 15 15 & 30
Dear sir, i want to NBCC & NTPC previous exam papers email Id : madhu_bingi@yahoo.co.in
residential projects,structural.
rcc floor to floor 4m. in column reinforcement where we provide lap in exact location.
How much quantity of rod binding work by a rod binder per day
what will be price of 1:2:4pcc per kg?