What is the difference between "working stress method"
And "limit state method"?
Answer Posted / nishant ratan bhardwaj
working stress method(WSM) 1- insure safety of structure against service load only
limit state method(LSM)1-insure safety of structure against both ultimATE and service load
WSM2-assumed to be deterministic because all load ,stresses ,factor of safety are already known
LSM2-non deterministic loads and stresses and load are predicted based on design data or experience of engineer
WSM3- based on linear stress distribution diagram
LSM3-based on non linier stress distribution diagram
WSM4- design values are obtained by applying factor of safety
LSM3- by applying paetial factor of safety
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
how to calculate Rate of analysis for 100 m3 Any ratio of concrete ? including labour
Dear Sir I Mahesh C. Bhamre have already given a Exam for Superintendent Officer / Public relation Officer Exam Dharmday Aaukta held at Nashik on Date 29/08/2010. My seat no was 5040247. and my cell no is 9822677994. and my mail Id is - mahesh.bhamre@rediffmail.com So can you pl send me details of result of respective exams. Thanking you in Anticipation.
how many type of admixtures for water stored structure?
As per Kandal suggestions, we have implemented rolling starts on 140 (+/- 5) degrees and we kept 3 rollars to complete the rolling before falling 125 degrees and the Aggregate AIV is below 22. But When the DBM bed is being rolled 3rd high viabration, (Before 1 plain & low ,2 high Viabrations), the aggregate is getting sharp edge agg. projections are damaged. As the literature is said that, the VG-30 Grade having better control the temp. susceptibility than Penetration grade. if so we could not get this problem at site. But we are facing on site. let me know.
How do you change a dimension value in solidsworks?
What is limit state method and working stress method and ultimate method
What are the problems one might face while having a Cantilever balcony?
foundation details for 25 ton weight Furnace on 2 supports and 2 tilters
in staad ,why we realease a moment of a member ? what is affect if we realease a moment
Exterior Joints,define
how many running meters in one kilogram of 4mm pvc coated chainlink fencing
what is the types of surveying?which type of survey carrying for type of work?
what is stressing
PCC Road Min Grade M 30 for VR standard Mahatashtra load 30 KN. what should be thickness of pavement, width 4m what should be length of panel.
rcc floor to floor 4m. in column reinforcement where we provide lap in exact location.