Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is fuction of NGT/NGR using in Generator.

Answer Posted / ahmed hussain

NGR is basically a resistor that Protects the Generator under Fault conditions, when phase to neutral fault occur ,the fault current is limited by NGR thus protecting the generator winding.
there are many NGR Configurations ,
1. LOW impedance
2.High impedance
3.Hybrid Impedance

Is This Answer Correct ?    0 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can tell us the AC indoor or outdoor which Tr and formulls

1719


We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......

2098


why and where we use early make & late break contacts in protection?

8247


Give atleast 20 alternating current apparatus and devices.

1717


why ct ,cvt should be stored in a vertical position?

2592


could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com

2028


Why star delta starter is preferred with induction motor?

1061


How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?

4413


Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?

2476


what parameters should we check to reduce the power bill

2275


defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?

3649


What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation

1844


what is circuit recombiner and how it is different from circuit breaker

1807


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

2040


Minimum IR value of 1.1 kv grade 3.5c (300, 240,185,150,120,95,70,50,35,25) sqmm Aluminium XLPE cable and 4c (16, 10,6 & 4) sqmm cu arm cable between RY,YB,BR,RN,YN,BN,RE,YE,BE & NE.

3295