if single phase is 230 v
three phase is 440 v
then what about two phase?and why is it so?
Answer Posted / karthik
292
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
where reactive power is used
How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?
why steady state stability limit is greater than transient stability limit ? How it can be explained ?
what is the interrelation between voltage current torgue speed and magnetic flux in case of different types of electric motors
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Explain the term parallel path in dc machin ?
CT Ratio of a energy meter connection is Red Phase : 100/5A, yello Phase : 50/5A & Blue phase : 100/5 A what is the overall Multiplication factor
What is difference between start imitation and start interlock for 3 phase motor protection ?
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
what is the question paper model for section engineer in RRB
I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions
Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?
what's the simultenous maximum demand (SMD)..what the diffrent MD and SMD?
1. Can a 12v DC choke operate a 60v/12w PL lamp ? 2. Can a 230v ballast fire / operate a 60v/12w PL lamps.
while starting a liquid starter ,is there any volage drop on water/soda on tank.can we touch the tank on starting?