Answer Posted / muchha mondal
in online ups system has two bypass one is static bypass which is work automatically when inverter off or any fault in inverter ckt the load is transfer to static bypass without interrupted, and anather is manual or maintanance bypass.the maintanance bypass use only for maintanance purpase it should be always off when ups working normal condition.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?
whether fibre optic cable in high voltage earth conductor is used for protection circuits
Apparent power is expressed as V * I(Conjugate). Why not in V * I ?
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
what is the minimum voltage require to injure our body?
This is urgent!! What is a Thyristor-based 3-ways selector switch with Zero crossing control? how does it operate and where is it mostly found in a system?
There are a trformer and an induction machine. Those two have the same supply. For which device the load current will be maximum? And why?
What is the lockout relay
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
ELECTRICAL ENGINEER TEST IN FEWA ANY ONE HAVE KNOWLEDGE ABOUT THIS?????????
Why line VTG = √3 phase VTG in star? How?
How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts
pls,send the previous year written test questions.
What is the purpose of stand by earth fault protection for transformer ?